Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Semin Thromb Hemost ; 48(7): 858-868, 2022 Oct.
Article in English | MEDLINE | ID: covidwho-2050628

ABSTRACT

Earlier variants of SARS-CoV-2 have been associated with hypercoagulability and an extensive formation of fibrin amyloid microclots, which are considered to contribute to the pathology of the coronavirus 2019 disease (COVID-19). The newer omicron variants appear to be far more transmissible, but less virulent, even when taking immunity acquired from previous infections or vaccination into account. We here show that while the clotting parameters associated with omicron variants are significantly raised over those of healthy, matched controls, they are raised to levels significantly lower than those seen with more severe variants such as beta and delta. We also observed that individuals infected with omicron variants manifested less extensive microclot formation in platelet-poor plasma compared with those harboring the more virulent variants. The measurement of clotting effects between the different variants acts as a kind of "internal control" that demonstrates the relationship between the extent of coagulopathies and the virulence of the variant of interest. This adds to the evidence that microclots may play an important role in reflecting the severity of symptoms observed in COVID-19.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Fibrin
2.
J Clin Med ; 11(3)2022 Feb 07.
Article in English | MEDLINE | ID: covidwho-1674681

ABSTRACT

Viscoelastic hemostatic assay (VHAs) are whole blood point-of-care tests that have become an essential method for assaying hemostatic competence in liver transplantation, cardiac surgery, and most recently, trauma surgery involving hemorrhagic shock. It has taken more than three-quarters of a century of research and clinical application for this technology to become mainstream in these three clinical areas. Within the last decade, the cup and pin legacy devices, such as thromboelastography (TEG® 5000) and rotational thromboelastometry (ROTEM® delta), have been supplanted not only by cartridge systems (TEG® 6S and ROTEM® sigma), but also by more portable point-of-care bedside testing iterations of these legacy devices (e.g., Sonoclot®, Quantra®, and ClotPro®). Here, the legacy and new generation VHAs are compared on the basis of their unique hemostatic parameters that define contributions of coagulation factors, fibrinogen/fibrin, platelets, and clot lysis as related to the lifespan of a clot. In conclusion, we offer a brief discussion on the meteoric adoption of VHAs across the medical and surgical specialties to address COVID-19-associated coagulopathy.

3.
Clin Case Rep ; 9(8): e04656, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1359778

ABSTRACT

Tension pneumomediastinum is a rare complication of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection that has increased in incidence with the novel coronavirus disease 2019 pandemic. Although traditionally managed with conservative measures, we present the indications and methods for the first operative management of tension pneumomediastinum with concomitant SARS-CoV-2 infection.

4.
Case Rep Med ; 2021: 5568982, 2021.
Article in English | MEDLINE | ID: covidwho-1343985

ABSTRACT

One of the complications of the novel coronavirus disease 2019 (COVID-19) is hypercoagulability. For this reason, patients presenting with COVID-19 are often put on therapeutic or intermediate anticoagulation upon hospitalization. A common issue of this anticoagulation is the progression to hypocoagulability resulting in hemorrhage. Therefore, monitoring the hemostatic integrity of critically ill COVID-19 patients is of utmost importance. In this case series, we present the cases of three coagulopathic COVID-19 patients whose anticoagulation was guided by thromboelastography (TEG). In each case, TEG permitted the clinical team to simultaneously prevent thrombotic and hemorrhagic events, a difficult task for COVID-19 patients admitted to the intensive care unit. The first two cases illustrate the utility of TEG to guide anticoagulant dosing for COVID-19 patients when the activated partial thromboplastin time (aPTT) is inaccurate. The first case was a severely ill COVID-19 patient with end-stage renal disease and a falsely elevated aPTT secondary to hypertriglyceridemia. The second case was a severely ill COVID-19 patient with chronic pulmonary disease who demonstrated a falsely elevated aPTT due to polycythemia and hemoconcentration. In both cases, TEG was sensitive to the hypercoagulability caused by the metabolic derangements which enabled the goal-directed titration of anticoagulants. The last case depicts a severely ill COVID-19 patient with an inherited factor V Leiden mutation who required abnormally high dosing to achieve therapeutic anticoagulation, guided by TEG. Hypercoagulopathic COVID-19 patients are difficult to anticoagulate without development of hypocoagulopathy. Treatment of these patients demands goal-directed therapy by diligent laboratory monitoring. This can be accomplished by the use of TEG coupled with aPTT to guide anticoagulation. This case series illustrates the necessity for active hemostatic monitoring of critically ill COVID-19 patients.

5.
Am J Case Rep ; 22: e931080, 2021 Apr 01.
Article in English | MEDLINE | ID: covidwho-1168169

ABSTRACT

BACKGROUND The novel coronavirus disease 2019 (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), often manifests a coagulopathy in severely ill patients, which may cause hemorrhage and/or thrombosis of varying severity. This report comprises the cases of 3 patients with COVID-19-associated coagulopathy who were evaluated with thromboelastography (TEG) and activated partial thromboplastin time (aPTT) to enable personalized anticoagulant therapy. CASE REPORT Three patients presented with COVID-19 pneumonia, confirmed by reverse transcription-polymerase chain reaction, who developed thrombohemorrhagic coagulopathy.Case 1: A 72-year-old woman on long-term warfarin therapy for a history of venous thromboembolism developed a right upper lobe pulmonary embolus, despite an international normalized ratio of 6.4 and aPTT of 120.7 s. TEG enabled successful anticoagulation with heparin, and her pulmonary infarct was no longer present 2 weeks later.Case 2: A 55-year-old woman developed a rectus sheath hematoma while on heparin, and TEG demonstrated increased fibrinolysis despite COVID-19 patients more commonly undergoing fibrinolytic shutdown.Case 3: A 43-year-old woman had significant thrombus burden while severely hypocoagulable according to laboratory testing. As the venous thrombi enlarged in a disseminated intravascular coagulopathic-like state, the heparin dose was escalated to achieve a target aPTT of 70 to 80 s, resulting in a flat line TEG tracing. CONCLUSIONS These 3 cases of COVID-19 pneumonia with complex and varied clinical histories demonstrated the clinical value of TEG combined with the measurement of aPTT to facilitate personalized anticoagulation, resulting in good clinical outcomes.


Subject(s)
Anticoagulants/therapeutic use , COVID-19/complications , Hemorrhage/drug therapy , Thrombelastography , Thrombolytic Therapy , Thrombosis/drug therapy , Adult , Aged , Female , Hemorrhage/virology , Heparin/therapeutic use , Humans , Middle Aged , Thrombosis/virology
SELECTION OF CITATIONS
SEARCH DETAIL